Top Sellers in Distribution Equipt - Power Transformers & Conditioners

   
Show  items per page    First Previous  Page   of  2  Next Last
DRY TYPE GENERAL PURPOSE TRANSFORMER
SQUARE D/TELEMECANIQUE
5S1F
5KVA TFMR
CONSTRUCTION EPOXY ENCAPSULATED, ENCLOSED, RAIN PROOF, ICE/SLEET PROOF; PRIMARY VOLTAGE 240 X 480 V; SECONDARY VOLTAGE 120/240 V; 60 HZ; POWER RATING 5 KVA; 1 PHASE; TEMPERATURE RISE 115 DEG C; WALL MOUNTING; NEMA 3R ENCLOSURE; SIZE 9.75 INCH W X 11.75 INCH D X 14.75 INCH H; WEIGHT 115 LB; APPLICATION INDOOR/OUTDOOR; APPROVAL UL 506, UL (CANADA AND US), CSA C22.2; APPLICABLE STANDARD NEMA ST-20; ENCLOSURE CODE TYPE 13B; INSULATION TEMPERATURE 180 DEG C; ENCLOSURE MATERIAL PAINTED STEEL

Show all:  General Purpose Dry Type Transformers 600v Or Less

 Spec Sheet   |   More Details
IN STOCK
INDUSTRIAL CONTROL TRANSFORMER
SQUARE D/TELEMECANIQUE
9070T250D1
TFMR
PRIMARY VOLTAGE 220 X 440 V, 230 X 460 V, 240 X 480 V; SECONDARY VOLTAGE 110/115/120 V; 50/60 HZ; POWER RATING 250 VA (UL/CSA/NOM), 160 VA (CE); INSULATION CLASS 130; SCREW TERMINAL; TEMPERATURE RISE 80 DEG C; 0.38 INCH L X 0.2 INCH W SLOT MOUNTING; SIZE 3.75 INCH W X 5.25 INCH D X 3.25 INCH H; EN 61558/01.89 APPLICABLE STANDARD; APPROVAL UL, CUL, CSA, CE, NOM; 9070T MODEL; NUMBER OF PHASE 1; WINDING MATERIAL COPPER

Show all:  Core & Coil Industrial Control Transformers

 Spec Sheet   |   More Details
IN STOCK
DRY TYPE GENERAL PURPOSE TRANSFORMER
SQUARE D/TELEMECANIQUE
2S1F
2KVA TFMR
CONSTRUCTION EPOXY ENCAPSULATED, ENCLOSED, RAIN PROOF, ICE/SLEET PROOF; PRIMARY VOLTAGE 240 X 480 V; SECONDARY VOLTAGE 120/240 V; 60 HZ; POWER RATING 2 KVA; 1 PHASE; TEMPERATURE RISE 115 DEG C; WALL MOUNTING; NEMA 3R ENCLOSURE; SIZE 8.68 INCH W X 6.56 INCH D X 9.56 INCH H; WEIGHT 39.1 LB; APPLICATION INDOOR/OUTDOOR; APPROVAL UL 506, UL (CANADA AND US), CSA C22.2; APPLICABLE STANDARD NEMA ST-20; ENCLOSURE CODE TYPE 9A; INSULATION TEMPERATURE 180 DEG C; ENCLOSURE MATERIAL PAINTED STEEL

Show all:  General Purpose Dry Type Transformers 600v Or Less

 Spec Sheet   |   More Details
DRY TYPE GENERAL PURPOSE TRANSFORMER
SQUARE D/TELEMECANIQUE
3S1F
3KVA TFMR
CONSTRUCTION EPOXY ENCAPSULATED, ENCLOSED, RAIN PROOF, ICE/SLEET PROOF; PRIMARY VOLTAGE 240 X 480 V; SECONDARY VOLTAGE 120/240 V; 60 HZ; POWER RATING 3 KVA; 1 PHASE; TEMPERATURE RISE 115 DEG C; WALL MOUNTING; NEMA 3R ENCLOSURE; SIZE 8.62 INCH W X 6.5 INCH D X 10.5 INCH H; WEIGHT 60 LB; APPLICATION INDOOR/OUTDOOR; APPROVAL UL 506, UL (CANADA AND US), CSA C22.2; APPLICABLE STANDARD NEMA ST-20; ENCLOSURE CODE TYPE 10A; INSULATION TEMPERATURE 180 DEG C; ENCLOSURE MATERIAL PAINTED STEEL

Show all:  General Purpose Dry Type Transformers 600v Or Less

 Spec Sheet   |   More Details
IN STOCK
IDEC
PS5R-SC24
24VDC 30W POWER SUPPLY

Show all:  Power Transformers, Etc. - Uninterruptible Power Supplies

 More Details
INDUSTRIAL CONTROL TRANSFORMER
SQUARE D/TELEMECANIQUE
9070T200D1
TFMR
PRIMARY VOLTAGE 220 X 440 V, 230 X 460 V, 240 X 480 V; SECONDARY VOLTAGE 110/115/120 V; 50/60 HZ; POWER RATING 200 VA; INSULATION CLASS 130; SCREW TERMINAL; TEMPERATURE RISE 80 DEG C; 0.38 INCH L X 0.2 INCH W SLOT MOUNTING; SIZE 3.75 INCH W X 3.59 INCH D X 3.2 INCH H; EN 61558/01.89 APPLICABLE STANDARD; APPROVAL UL, CUL, CSA, CE, NOM; 9070T MODEL; NUMBER OF PHASE 1; WINDING MATERIAL COPPER

Show all:  Core & Coil Industrial Control Transformers

 Spec Sheet   |   More Details
IN STOCK
INDUSTRIAL CONTROL TRANSFORMER
SQUARE D/TELEMECANIQUE
9070T75D1
TFMR
PRIMARY VOLTAGE 220 X 440 V, 230 X 460 V, 240 X 480 V; SECONDARY VOLTAGE 110/115/120 V; 50/60 HZ; POWER RATING 75 VA; INSULATION CLASS 105; SCREW TERMINAL; TEMPERATURE RISE 55 DEG C; 0.48 INCH L X 0.2 INCH W SLOT MOUNTING; SIZE 3.38 INCH W X 3.34 INCH D X 2.89 INCH H; EN 61558/01.89 APPLICABLE STANDARD; APPROVAL UL, CUL, CSA, CE, NOM; 9070T MODEL; NUMBER OF PHASE 1; WINDING MATERIAL COPPER

Show all:  Core & Coil Industrial Control Transformers

 Spec Sheet   |   More Details
IN STOCK
INDUSTRIAL CONTROL TRANSFORMER
SQUARE D/TELEMECANIQUE
9070T500D1
TFMR
PRIMARY VOLTAGE 220 X 440 V, 230 X 460 V, 240 X 480 V; SECONDARY VOLTAGE 110/115/120 V; 50/60 HZ; POWER RATING 500 VA (UL/CSA/NOM), 300 VA (CE); INSULATION CLASS 180; SCREW TERMINAL; TEMPERATURE RISE 115 DEG C; 0.38 INCH L X 0.2 INCH W SLOT MOUNTING; SIZE 4.5 INCH W X 5.46 INCH D X 3.8 INCH H; EN 61558/01.89 APPLICABLE STANDARD; APPROVAL UL, CUL, CSA, CE, NOM; 9070T MODEL; NUMBER OF PHASE 1; WINDING MATERIAL COPPER

Show all:  Core & Coil Industrial Control Transformers

 Spec Sheet   |   More Details
IN STOCK
INDUSTRIAL CONTROL TRANSFORMER
SQUARE D/TELEMECANIQUE
9070T150D1
TFMR
PRIMARY VOLTAGE 220 X 440 V, 230 X 460 V, 240 X 480 V; SECONDARY VOLTAGE 110/115/120 V; 50/60 HZ; POWER RATING 150 VA; INSULATION CLASS 105; SCREW TERMINAL; TEMPERATURE RISE 55 DEG C; 0.38 INCH L X 0.2 INCH W SLOT MOUNTING; SIZE 3.75 INCH W X 3.59 INCH D X 3.2 INCH H; EN 61558/01.89 APPLICABLE STANDARD; APPROVAL UL, CUL, CSA, CE, NOM; 9070T MODEL; NUMBER OF PHASE 1; WINDING MATERIAL COPPER

Show all:  Core & Coil Industrial Control Transformers

 Spec Sheet   |   More Details
IN STOCK
IDEC
PS5R-SC12
12VDC 30 WATT POWER SUPPLY

Show all:  Power Transformers, Etc. - Uninterruptible Power Supplies

 More Details
IN STOCK
DRY TYPE GENERAL PURPOSE TRANSFORMER
SQUARE D/TELEMECANIQUE
1S1F
1.0KVA TFMR
CONSTRUCTION EPOXY ENCAPSULATED, ENCLOSED, RAIN PROOF, ICE/SLEET PROOF; PRIMARY VOLTAGE 240 X 480 V; SECONDARY VOLTAGE 120/240 V; 60 HZ; POWER RATING 1 KVA; 1 PHASE; TEMPERATURE RISE 115 DEG C; WALL MOUNTING; NEMA 3R ENCLOSURE; SIZE 6.94 INCH W X 5.31 INCH D X 8.13 INCH H; WEIGHT 21.2 LB; APPLICATION INDOOR/OUTDOOR; APPROVAL UL 506, UL (CANADA AND US), CSA C22.2; APPLICABLE STANDARD NEMA ST-20; ENCLOSURE CODE TYPE 7A; INSULATION TEMPERATURE 180 DEG C; ENCLOSURE MATERIAL PAINTED STEEL

Show all:  General Purpose Dry Type Transformers 600v Or Less

 Spec Sheet   |   More Details
IN STOCK
INDUSTRIAL CONTROL TRANSFORMER
SQUARE D/TELEMECANIQUE
9070T50D1
TFMR
PRIMARY VOLTAGE 220 X 440 V, 230 X 460 V, 240 X 480 V; SECONDARY VOLTAGE 110/115/120 V; 50/60 HZ; POWER RATING 50 VA; INSULATION CLASS 105; SCREW TERMINAL; TEMPERATURE RISE 55 DEG C; 0.38 INCH L X 0.2 INCH W SLOT MOUNTING; SIZE 3 INCH W X 3.09 INCH D X 2.558 INCH H; EN 61558/01.89 APPLICABLE STANDARD; APPROVAL UL, CUL, CSA, CE, NOM; 9070T MODEL; NUMBER OF PHASE 1; WINDING MATERIAL COPPER

Show all:  Core & Coil Industrial Control Transformers

 Spec Sheet   |   More Details
IN STOCK
INDUSTRIAL CONTROL TRANSFORMER
SQUARE D/TELEMECANIQUE
9070T100D1
TFMR
PRIMARY VOLTAGE 220 X 440 V, 230 X 460 V, 240 X 480 V; SECONDARY VOLTAGE 110/115/120 V; 50/60 HZ; POWER RATING 100 VA; INSULATION CLASS 105; SCREW TERMINAL; TEMPERATURE RISE 55 DEG C; 0.48 INCH L X 0.2 INCH W SLOT MOUNTING; SIZE 3.38 INCH W X 3.34 INCH D X 2.89 INCH H; EN 61558/01.89 APPLICABLE STANDARD; APPROVAL UL, CUL, CSA, CE, NOM; 9070T MODEL; NUMBER OF PHASE 1; WINDING MATERIAL COPPER

Show all:  Core & Coil Industrial Control Transformers

 Spec Sheet   |   More Details
IN STOCK
INDUSTRIAL CONTROL TRANSFORMER
SQUARE D/TELEMECANIQUE
9070T300D1
TFMR
PRIMARY VOLTAGE 220 X 440 V, 230 X 460 V, 240 X 480 V; SECONDARY VOLTAGE 110/115/120 V; 50/60 HZ; POWER RATING 300 VA (UL/CSA/NOM), 200 VA (CE); INSULATION CLASS 130; SCREW TERMINAL; TEMPERATURE RISE 80 DEG C; 0.38 INCH L X 0.2 INCH W SLOT MOUNTING; SIZE 4.5 INCH W X 4.7 INCH D X 3.8 INCH H; EN 61558/01.89 APPLICABLE STANDARD; APPROVAL UL, CUL, CSA, CE, NOM; 9070T MODEL; NUMBER OF PHASE 1; WINDING MATERIAL COPPER

Show all:  Core & Coil Industrial Control Transformers

 Spec Sheet   |   More Details
IN STOCK
IDEC
PS5R-SD24
60W 24VDC POWER SUPPLY

Show all:  Power Transformers, Etc. - Uninterruptible Power Supplies

 More Details